faces/pulsometer: remember pulsometer measurement
Avoid resetting it to zero when the face is activated. Initialize the variables once when the face is first set up. This makes it remember the last measurement taken by the user. It will no longer be overwritten when the watch face activates.
This commit is contained in:
@@ -139,7 +139,11 @@ void pulsometer_face_setup(movement_settings_t *settings, uint8_t watch_face_ind
|
||||
|
||||
if (*context_ptr == NULL) {
|
||||
pulsometer_state_t *pulsometer = malloc(sizeof(pulsometer_state_t));
|
||||
|
||||
pulsometer->calibration = PULSOMETER_FACE_CALIBRATION_DEFAULT;
|
||||
pulsometer->pulses = 0;
|
||||
pulsometer->ticks = 0;
|
||||
|
||||
*context_ptr = pulsometer;
|
||||
}
|
||||
}
|
||||
@@ -150,8 +154,6 @@ void pulsometer_face_activate(movement_settings_t *settings, void *context) {
|
||||
pulsometer_state_t *pulsometer = context;
|
||||
|
||||
pulsometer->measuring = false;
|
||||
pulsometer->pulses = 0;
|
||||
pulsometer->ticks = 0;
|
||||
|
||||
pulsometer_display_title(pulsometer);
|
||||
pulsometer_display_calibration(pulsometer);
|
||||
|
||||
Reference in New Issue