nanosec: use new Movement API for getting temperature
This commit is contained in:
parent
f48058568a
commit
ea90319180
@ -25,7 +25,6 @@
|
||||
#include <stdlib.h>
|
||||
#include <string.h>
|
||||
#include <math.h>
|
||||
#include "thermistor_driver.h"
|
||||
#include "nanosec_face.h"
|
||||
#include "filesystem.h"
|
||||
#include "watch_utility.h"
|
||||
@ -329,10 +328,12 @@ bool nanosec_face_loop(movement_event_t event, void *context) {
|
||||
break;
|
||||
case EVENT_BACKGROUND_TASK:
|
||||
// Here we measure temperature and do main frequency correction
|
||||
thermistor_driver_enable();
|
||||
float temperature_c = thermistor_driver_get_temperature();
|
||||
float temperature_c = movement_get_temperature();
|
||||
float voltage = (float)watch_get_vcc_voltage() / 1000.0;
|
||||
thermistor_driver_disable();
|
||||
|
||||
// If temperature is 0xFFFFFFFF, no temperature sensor is installed.
|
||||
// Should we assume nominal temperature here? Seems better than aborting.
|
||||
if (temperature_c == 0xFFFFFFFF) temperature_c = nanosec_state.center_temperature;
|
||||
// L22 correction scaling is 0.95367ppm per 1 in FREQCORR
|
||||
// At wrong temperature crystall starting to run slow, negative correction will speed up frequency to correct
|
||||
// Default 32kHz correciton factor is -0.034, centered around 25°C
|
||||
|
||||